.elementor-heading-title{padding:0;margin:0;line-height:1}.elementor-widget-heading .elementor-heading-title[class*=elementor-size-]>a{color:inherit;font-size:inherit;line-height:inherit}.elementor-widget-heading .elementor-heading-title.elementor-size-small{font-size:15px}.elementor-widget-heading .elementor-heading-title.elementor-size-medium{font-size:19px}.elementor-widget-heading .elementor-heading-title.elementor-size-large{font-size:29px}.elementor-widget-heading .elementor-heading-title.elementor-size-xl{font-size:39px}.elementor-widget-heading .elementor-heading-title.elementor-size-xxl{font-size:59px}
Category: OTDR
Core features
● Long-haul network testing
● Access network testing
● FTTx/PON testing through splitters
● Compact, rugged, light weight 0.7kg
● All new UI design with innovation
● 32dB Dynamic range
● 1m Event dead zone
● Bult-in OPM、SLS、VFL、RJ45、FIP modules
● Link Map & Pass/Fail judgment functions
● Dual wavelengths testing
Recommended Products
OTDR
/*! elementor – v3.23.0 – 05-08-2024 */
.elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[src$=”.svg”]{width:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block}
/*! elementor – v3.23.0 – 05-08-2024 */
.elementor-image-gallery .gallery-item{display:inline-block;text-align:center;vertical-align:top;width:100%;max-width:100%;margin:0 auto}.elementor-image-gallery .gallery-item img{margin:0 auto}.elementor-image-gallery .gallery-item .gallery-caption{margin:0}.elementor-image-gallery figure img{display:block}.elementor-image-gallery figure figcaption{width:100%}.gallery-spacing-custom .elementor-image-gallery .gallery-icon{padding:0}@media (min-width:768px){.elementor-image-gallery .gallery-columns-2 .gallery-item{max-width:50%}.elementor-image-gallery .gallery-columns-3 .gallery-item{max-width:33.33%}.elementor-image-gallery .gallery-columns-4 .gallery-item{max-width:25%}.elementor-image-gallery .gallery-columns-5 .gallery-item{max-width:20%}.elementor-image-gallery .gallery-columns-6 .gallery-item{max-width:16.666%}.elementor-image-gallery .gallery-columns-7 .gallery-item{max-width:14.28%}.elementor-image-gallery .gallery-columns-8 .gallery-item{max-width:12.5%}.elementor-image-gallery .gallery-columns-9 .gallery-item{max-width:11.11%}.elementor-image-gallery .gallery-columns-10 .gallery-item{max-width:10%}}@media (min-width:480px) and (max-width:767px){.elementor-image-gallery .gallery.gallery-columns-2 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-3 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-4 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-5 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-6 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-7 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-8 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-9 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-10 .gallery-item{max-width:50%}}@media (max-width:479px){.elementor-image-gallery .gallery.gallery-columns-2 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-3 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-4 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-5 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-6 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-7 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-8 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-9 .gallery-item,.elementor-image-gallery .gallery.gallery-columns-10 .gallery-item{max-width:100%}}
DescriptionFeatures Intelligent multi-function OTDR● Dynamic range 32dB
● 1m short event blind zone
● One-key measurement of all events Engineering machines are widely used● Toll network testing
● Access network testing
● FTTx/PON network splitter testing Application Scenario● Optical Network Terminal (ONT)
● Drop terminal
● Fiber distribution hub (FDH) for FTTH distribution (F2) fiber characterization
● Troubleshooting and troubleshooting All in one machine● Optical Time Domain Reflectometer (OTDR)
● Visual Fault Locator (VFL)
● Optical Power Meter (OPM)
● Stabilized Light Source (SLS)
● Face inspection (FIP)
● Network test (RJ45) 4 measurement modes – meet any measurement needs● Real-time test
● Average test
● Intelligent automatic
● Expert manual Dual Wavelength Test● 1310nm
● 1550nm
● Simultaneous testing of 1310nm+1550nm Brand-new UI design that subverts the industry● 3.5-inch color LCD screen
● Clear colors, simple and clear interface design
● Quickly find the required function setting items Smart Curve Analysis● Don’t miss any event
● Understand the loss of cable breakage, length, bend, splice point, connector, etc. through the curve log each event● 3 event parameter information can be viewed at the same time
● Optical cable break point, loss, length, bend, connector, etc., on the waveform, the loss or reflection obtained by the test is expressed as an event
dustproof and dropproof
Link Summary● Display curve graph, link [length], total attenuation and attenuation coefficient Optical link analysis● Icons display event test results
● Simple and intuitive graphical interface, displaying information such as fiber link length, event point type, breakpoint location, etc. One-key test, immediately isolate and evaluate fiber faults
dustproof and dropproof
Splitter Loss Test● Can test 3-stage splitter
● Can test up to 1:32 channels User self-calibration and easy maintenance● Built-in [self-calibration] function
● Shorten maintenance time
● Reduce maintenance cost Support PC analysis operation● Powerful data processing functions
● Analyze and display OTDR related information
● Support printing files and setting output content Silicone sheath● Adopt new rubber sheath
● Analyze and display OTDR related information
● Effectively reduce damage and prolong service life interface● SC
● ST (optional)
● FC (optional)
● LC (optional)
Specification
OTDR Specifications | |||
Model | KL-6200-S | KL-6200-P | |
Wavelength (nm) | SM 1310/1550 | PON 1310/1550/1625 (built-in filter) | |
Dynamic range (dB) | 32/30 | 32/30/28 | |
Number of optical port | 1 | 2 | |
Applicable fiber | SM (ITU-T G.652) | ||
Distance range (km) | 0.5,1,2,5,10,20,35,50,75,100,150,200 | ||
Pulse width (ns) | 5,10,20,50,100,200,500,1000,2000,10000,20000 | ||
Event dead zone*1 (m) | 1 | ||
Attenuation dead zone*2 (m) | 3.5 | ||
Number of sampling points | Max.80000 | Max.80000 | |
Sampling resolution | Min.0.04m | ||
Distance measurement accuracy | ±(0.75 m + Measurement distance × 2 × 10−5 + Sampling resolution) | ||
Loss measurement accuracy | ±0.03 dB/dB | ||
Return loss measurement accuracy | ±2 dB | ||
Optical Power Meter Module (Built-in) | √ | × | |
OPM | Wavelength (nm) | 800 ~ 1650nm | |
Power range | -70 ~ +6dBm | ||
Measure accuracy | <(±0.2dB or ±5%) | ||
Display resolution | 0.01dB | ||
Optical input port | SC/UPC + 2.5mm Universal ferrule | ||
Stabilized Light Source Module (Built-in) | √ | √ | |
SLS | Wavelength (nm) | 1310/1550 | |
Output power | ≥-10dBm | ||
Modulation mode | CW, 270 Hz, 1 kHz, 2 kHz | ||
Laser class | Class 1M or Class 1 | ||
Optical input port | OTDR port | ||
Visual Fault Locator Module (Built-in) | √ | √ | |
VFL | Wavelength (nm) | 650 | |
Output power | 10mW | ||
Modulation mode | CW, CHOP (2 Hz) | ||
Laser class | Class 3R | ||
Optical input port | 2.5 mm Universal ferrule type | ||
Fiber Inspection Probe (Built-in) | Optional | Optional | |
FIP | Magnification | Magnification 250X | |
Resolution(um) | ≥1.0 | ||
Electrical interface | USB2.0 | ||
Optical Connector | FC/UPC,SC/UPC,ST/UPC | ||
Sensor | 1/3 inch | ||
√ | √ | ||
RJ45 | Wavelength (nm) | CAT5, CAT6 | |
Distance of Cable Collationl | 300m | ||
Distance of emitting signal | 300m | ||
General Specifications | |||
Link Map | √ | ||
Pass/Fail judgment | √ | ||
Distance unit | m, km, mile, ft, kft | ||
PC Analysis Software | √ | ||
Languages | English, Español, Chinese, Português, Français, Русский | ||
Optical connector | SC/UPC (FC/UPC,ST/UPC,LC/UP is Optional) | ||
Display | 3.5-inch color TFT LCD (Resolution: 640 × 480) | ||
Electrical interface | Charge port × 1, USB 2.0 × 3, RJ45 × 2 | ||
Operating temperature | -10 ~ 50°C (0 ~ 40°C when AC adapter is being used. 0 to 35°C when battery is be charged) | ||
Storage temperature | -20 to 60°C | ||
Altitude | 4000 m | ||
Humidity | 0 to 90% RH (20 to 90% with 739874 AC adapter, non-condensing) | ||
Power requirements | 100 – 240V AC, 50/60Hz (AC adapter) | ||
Battery | 3000mAh | ||
LED Light illumination | ≥15000mcd | ||
Operating time*3 | 5 hours | ||
Data storage | Internal storage: ≥1000 waveforms, External storage: USB memory | ||
Dimensions | 118 mm (W) × 218 mm (H) × 55 mm (D) | ||
Weight | Approx. 0.73 kg (including internal battery and protectors, excluding OTDR unit and options) |
Notes:
1. Minimum pulse width, return loss: ≥55 dB (≥40 dB for 850/1300 nm), group refractive index: 1.5, at 1.5 dB below the unsaturated peak level.
2. Minimum pulse width, group refractive index: 1.5, at a point where the backscatter level is within ±0.5dB of the normal level. For SMF, at 1310nm, return loss: ≥55dB.
3. New Battery
All specifications valid at 23°C ± 2°C (73.4°F ± 3.6°F) unless otherwise specified.
DownloadProduct manual PDF
TutorialsProducts Tutorials
ConfigurationHello World …
Showing 1–6 of 32 results